Sign In | Join Free | My himfr.com
Home > Mold Temperature Controller >

Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control

    Buy cheap Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control from wholesalers
     
    Buy cheap Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control from wholesalers
    • Buy cheap Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control from wholesalers
    • Buy cheap Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control from wholesalers
    • Buy cheap Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control from wholesalers
    • Buy cheap Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control from wholesalers

    Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control

    Ask Lasest Price
    Brand Name : ORSTE
    Model Number : OMT-605-W ~ OMT-1010-HTW
    Certification : CE, ISO, SGS
    Price : 1,300~2,400USD/Set
    Payment Terms : TT, LC, Paypal, West Union, Cash
    Supply Ability : 500-3000 Sets / Year
    Delivery Time : 7-15 days
    • Product Details
    • Company Profile

    Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control

    Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control

    OMT-W Mold Temperature Controller Water Heater.pdf...


    Product Features of Water Heater Temperature Controller


    • Equipped with the design of one week automatic start/stop timer, screen can be converted between Chinese and English.
    • P. I. D. multi-stage temperature control system can maintain a mold temperature with an accuracy of ±1oC.
    • Adopts high efficiency water cycle pump, which can meet the demands of temperature control for precise molds and mold loop with minor diameter to achieve precise temperature control and high efficiency heat exchange. Pump inside adopts stainless steel to avoid explosion.
    • Multiple safety devices including power reverse phase protection, pump overload protection, overheat protection and low level protection that can automatically detect abnormal performance and indicate this via visible alarm.
    • For standard OMT-W, the heating temperature can reach 120oC, while for OMT-HTW, it can reach 180oC.
    • Equipped with high pressure protection, safety pressure relieving, automatic water supplying and air exhausting.
    • For OMT-W, direct cooling is adopted. Automatic water supplying device ensures fast heat exchange.

    Application of Water Heater Temperature Controller


    OMT-W series water heaters are widely used in the production of plastic product. They are mainly applied to heat up the mold and maintain temperature, also they can be used in other similar fields. Through the principle of heat exchange, they can shorten the product mold cycle and improve production efficiency.


    PARAMETERS of Water Heater Temperature Controller


    Model

    Max Temp. (℃)

    Pipe Heater (kw)

    Pump Power (kw)

    Max. Pump Flow (L/Min)

    Max. Pump Pressure (bar)

    Heating Tank Number

    Cooling Method

    Cooling Water pipe (inch)

    Circulating Water Pipe (inch)

    Dimensions
    (H*W*D) (mm)

    Weight (kg)

    OMT-605-W

    120


    6

    0.375

    42

    2.5

    1

    Direct Cooling

    1/2"

    3/8"

    580*260*650

    34

    OMT-610-W

    6

    0.75

    42

    1

    730*300*660

    36

    OMT-610-WD

    6*2

    0.75*2

    42*2

    2

    980*390*860

    72

    OMT-910-W

    9

    0.75

    56

    1

    730*300*660

    36

    OMT-910-WD

    9*2

    0.75*2

    56*2

    2

    980*390*860

    72

    OMT-1220-W

    12

    1.5

    235

    1

    980*390*860

    68

    OMT-2430-W

    24

    2.2

    315

    2

    980*390*860

    75

    OMT-3650-W

    36

    3.75

    495

    3

    980*390*860

    83

    OMT-1010-HTW

    160

    10

    0.75

    78


    1

    Indirect Cooling

    980*390*860

    70


    Machine Details of Water Heater Temperature Controller



    Notes of Maintenance


    1) Turn off the main switch and control switch and unplug the cord from power supply before service and maintenance.

    2) Be sure not to modify electrical wiring or reassemble the electrical components inside of the control box.

    3) Always refer to the electrical diagram of this manual to check and maintain the electrical wiring problems.

    4) Service and maintenance of the electrical parts should only be carried out by qualified electricians.


    Exemption Clause


    The following statements clarify the responsibilities and regulations born by any buyer or user who purchases products and accessories from ORSTE (including employees and agents).

    ORSTE is exempted from liability for any costs, fees, claims and losses caused by reasons below:

    1. Any careless or man-made installations, operation and maintenances upon machines without referring to the Manual prior to machine using.

    2. Any incidents beyond human reasonable controls, which include man-made vicious or deliberate damages or abnormal power, and machine faults caused by irresistible natural disasters including fire, flood, storm and earthquake.

    3. Any operational actions that are not authorized by ORSTE upon machine, including adding or replacing accessories, dismantling, delivering or repairing.

    4. Employing consumables or oil media that are not appointed by ORSTE.

    Quality Industrial Mold Temperature Controller SUS Steel Water Heater Temp Control for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Orste Machinery Equipment Co., Ltd.
    *Subject:
    *Message: